Cookie Consent by Free Privacy Policy website

Compression load cell COLVIS


Download PDF

Standard power supply with batteries and external battery charger or optional with external power supply and/or RS485.

Optional cable with female connector UTS6JC10E6S, 5 meters - 4 x 0.25 mm² for RS485 and external power supply.


Zoom Click to enlarge image

Compression load cell COLVIS

Technical Specifications

MaterialStainless steel
Nominal load100, 200, 300 t
Limit load150 % of full scale
Breaking load300 % of full scale
Supply voltage5 - 13 VDC
Max absorption1,5 W
Protection classIP 54
Display5 digits, red LED
Internal resolution24 bit
Digital filter0.1 - 50 Hz
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means